Optima Tele.com logo
  
Home About Us News Products Support Contact Partners Site Map Log In






T:LAN NetPro e4x
0-2 WAN, 4 Ethernet, 4 Serial ports
T:LAN NetStream 24x
2 WAN, 4 Ethernet, 2 or 4 Serial ports, Dual WAN PipeLine mode, VLAN mapping



Optima NMS
Network Monitoring System
RIO 1608R8S4B
16 Digital, 8 Analog Inputs, 8 Relay Outputs, 4 Serial Ports
RIO 4802B
48 Digital, 2 Analog Inputs
RIO 4002R8B
40 Digital, 2 Analog Inputs, 8 Relay Outputs
RIO 4802B+4802E
96 Digital, 4 Analog Inputs
RIO 4802B+4002R8E
88 Digital, 4 Analog Inputs, 8 Relay Outputs
RIO 4002R8B+4002R8E
80 Digital, 4 Analog Inputs, 16 Relay Outputs



T:LAN Remote Commander
See how the T:LAN Remote Commander facilitiates remote management and maintenance of the entire T:LAN product family.
Mapping Out Your VLAN Strategy
The T:LAN NetStream Series delivers cost-effective solutions for transporting Customer VLANs end-to-end.
Optima's SDCoIP
Optima's SDCoIP can dramatically shorten turnaround times when techs respond to network problems and saves money in the process.
WAN Pipelines
Easily aggregate WAN circuits for superior bandwidth utilization with the Optima T:LAN NetPlex/NetStream Series.







RIO 4802B+4802E

FEATURES
  • 96 Discrete Alarm Inputs
  • 4 Analog Inputs
  • VT100, Telnet, SNMP Manageable
  • Low Power, Compact Design
TECHNICAL SPECIFICATIONS

PHYSICAL
Width
41.91cm (16.50”)
Height
2.54cm (1.00”)
Depth
6.99cm (2.75”)
Weight
~1100g
Mounting
Rack mounting: 1U. Two units can be installed side-by-side using an optional bracket for standard 19” rack installations. Also supports tabletop, shelf and wall mounting.

POWER
Input
5VDC, max. 50mA
No separate power supply required as RIO modules are powered from Optima T:LAN unit.
Power Consumption
Less than 1/4 Watt
Connector
Power fed to module through the datacom RJ45 jack.

ENVIRONMENTAL
Temperature
0 to 50ºC (32 to 122ºF)
Humidity
Up to 80% relative humidity (non-condensing)

DATA
Connector
Dual RJ45, shielded
Type
Optima proprietary: communication with the first RIO Base module is through the T:LAN Expansion Port. Additional RIO Base modules are daisy chained from the first via their dual RJ45 interface jacks. RIO Expansion modules connect to RIO Base modules via an inter-module base expansion header.
Distance
Up to 10m (30ft)
Cabling
UTP, Category 5 (wired EIA568B standard straight-through)

CONTACT INPUTS
Inputs
96
ground referenced, triggered by switching to ground or applying a negative voltage
Voltage Tolerance
Up to -60VDC
Wiring
One contact per pair (24 contacts/connector)
Connector
Four 25-pair Telco Connectors (female)
Cabling
UTP, Category 3 or better recommended

ANALOG INPUTS
Inputs
4 single ended
Sensing Range
Input 1: -6.4VDC to +6.4VDC
Input 2: -64VDC to +64VDC
Input 3: -6.4VDC to +6.4VDC
Input 4: -64VDC to +64VDC
Resolution
Input 1: 50mVDC
Input 2: 0.5VDC
Input 3: 50mVDC
Input 4: 0.5VDC
Wiring/Connector
Last pair of each 25-pair connector
Cabling
UTP, Category 3 or better recommended

Temperature sensor
Range/Resolution
-55ºC to +100ºC, 0.0625ºC

INDICATOR
LED
Power/Error/Activity

MANAGEMENT
Protocols
VT-100, TELNET and SNMP through Optima T:LAN unit

Printable versionSend via e-mailAdd to FavoritesPage top


Related Files

Optima RIO System Brochure
4000-B800003C
1464KB

© Copyright 2000 - 2008 Optima Tele.com, Inc. All rights reserved.
Terms of use & Privacy Statement